System Event Log - Event Configuration

When the Syslog/SMTP checkbox is marked, the event log will be sent to

system log server/SMTP server. Also, per port log (link up, link down, and

both) events can be sent to the system log server/SMTP server with the

respective checkbox ticked. After configuring, click

Apply

to have the

setting taken effect.

System event selection: There are 4 event types

—Device cold start,

Device warm start, Authentication Failure, and X-ring topology change.

Before you can tick the checkbox of each event type, the Syslog Client

Mode column on the Syslog Configuration tab/E-mail Alert column on

the SMTP Configuration tab must be enabled first.

Device cold start: When the device executes cold start action, the

system will issue a log event.

Device warm start: When the device executes warm start, the

system will issue a log event.

Authentication Failure: When the SNMP authentication fails, the

system will issue a log event.

X-ring topology change: When the X-ring topology has changed,

the system will issue a log event.

Port event selection: Also, before the drop-down menu items are

available, the Syslog Client Mode column on the Syslog Configuration

tab and the E-mail Alert column on the SMTP Configuration tab must

be enabled first. Those drop-down menu items have 3 selections

—Link

UP, Link Down, and Link UP & Link Down. Disable means no event will

be sent to the system log server/SMTP server.

Link UP: The system will issue a log message when port

connection is up only.

Link Down: The system will issue a log message when port

connection is down only.

Link UP & Link Down: The system will issue a log message when

port connection is up and down.