Trouble shooting
Verify that you are using the right power cord/adapter (DC 12 ~ 48V).
Please
don‘t use the power adapter with DC output higher than 48V, or
this switch will be burned down.
Select the proper UTP/STP cable to construct the user network. Use
unshielded twisted-pair (UTP) or shield twisted-pair (STP) cable for
RJ-45 connections: 100 Ω Category 3, 4 or 5 cable for 10Mbps
connections, 100Ω Category 5 cable for 100Mbps connections, or 100
Ω Category 5e/above cable for 1000Mbps connections. Also be sure
that the length of any twisted-pair connection does not exceed 100
meters (328 feet).
Diagnosing LED Indicators: To assist in identifying problems, the
switch can be easily monitored through panel indicators, which
describe common problems the user may encounter and where the
user can find possible solutions.
If the power indicator does not light on when the power cord is plugged
in, you may have a problem with power cord. Then check for loose
power connections, power losses or surges at power outlet. If you still
cannot resolve the problem, contact the local dealer for assistance.
If the LED indicators are normal and the connected cables are correct
but the packets still cannot be transmitted. Please check the user
system
‘s Ethernet devices‘ configuration or status.