beautypg.com

Ds1875 pon triplexer and sfp controller – Rainbow Electronics DS1875 User Manual

Page 52

background image

DS1875

PON Triplexer and SFP Controller

52

______________________________________________________________________________________

Lower Memory, Register 74h: WARN

3

POWER-ON

VALUE

10h

READ

ACCESS All

WRITE

ACCESS N/A

MEMORY

TYPE Volatile

74h

TEMP HI

TEMP LO

VCC HI

VCC LO

MON1 HI

MON1 LO

MON2 HI

MON2 LO

BIT

7

BIT

0

BIT

7

TEMP HI: High warning status for temperature measurement.
0 = (Default) Last measurement was equal to or below threshold setting.
1 = Last measurement was above threshold setting.

BIT

6

TEMP LO: Low warning status for temperature measurement.
0 = (Default) Last measurement was equal to or above threshold setting.
1 = Last measurement was below threshold setting.

BIT

5

VCC HI: High warning status for V

CC

measurement.

0 = (Default) Last measurement was equal to or below threshold setting.
1 = Last measurement was above threshold setting.

BIT

4

VCC LO: Low warning status for V

CC

measurement. This bit is set when the V

CC

supply is below the

POA trip point value. It clears itself when a V

CC

measurement is completed and the value is above the

low threshold.
0 = Last measurement was equal to or above threshold setting.
1 = (Default) Last measurement was below threshold setting.

BIT

3

MON1 HI: High warning status for MON1 measurement.
0 = (Default) Last measurement was equal to or below threshold setting.
1 = Last measurement was above threshold setting.

BIT

2

MON1 LO: Low warning status for MON1 measurement.
0 = (Default) Last measurement was equal to or above threshold setting.
1 = Last measurement was below threshold setting.

BIT

1

MON2 HI: High warning status for MON2 measurement.
0 = (Default) Last measurement was equal to or below threshold setting.
1 = Last measurement was above threshold setting.

BIT

0

MON2 LO: Low warning status for MON2 measurement.
0 = (Default) Last measurement was equal to or above threshold setting.
1 = Last measurement was below threshold setting.