AC CHARACTERISTICS – TRANSMIT SIDE

(0

°

C to 70

°

C; V

DD

=5V + 5%)

(–40

°

C to +85

°

C for DS2151QN)

PARAMETER

SYMBOL

MIN

TYP

MAX

UNITS

NOTES

TCLK Period

t

P

648

ns

TCLK Pulse Width

t

CH

t

CL

75
75

ns
ns

TSER and TLINK Set Up to TCLK
Falling

t

SU

25

ns

1

TSER and TLINK Hold from
TCLK Falling

t

HD

25

ns

1

TSYNC Setup to TCLK Falling

t

SU

25

t

CH

–5

TSYNC Pulse Width

t

PW

50

TCLK Rise/Fall Times

t

R

, t

F

25

ns

Delay TCLK to TCHCLK

t

D1

10

60

ns

Delay TCLK to TCHBLK

t

D2

10

70

ns

Delay TCLK to TSYNC

t

D3

10

60

ns

Delay TCLK to TLCLK

t

D4

10

60

ns

NOTE:

1. If the transmit side elastic store is enabled, then TSER is sampled on the falling edge of SYSCLK and the parame-

ters t

SU

and t

HD

still apply.