V-Tech CAT5 System Technical Guide User Manual
Page 29

Page 29
K5 System Technical Guide
station only
• JWB (OUT): Bus Signal Output. RJ45 port includes audio, data & video. It can be connected to
distributor.
• CN-MDS: Bus Signal Input. RJ45 port, connected to MDS only
• CN-NET: RJ45 Network Port, connected to LAN
• JP1/JP2/JP3: Jumper. Removed if C5-MDS connected
• SWI: Distributor Setting. Match different distributor
Specifications
Power input:
DC 24V
Standby Current:
185mA
Working Current:
250mA
Video Signal:
CCIR, 1Vp-p, 75Ω
Audio Signal:
300~3,400 KHz, 0~240 mV
Transmission Mode:
TCP/IP
Connection Port:
RJ45
Network Interface:
Standard Ethernet interface
Working temperature:
-10
0
C ~ +40
0
C
Dimension:
140*150*60 mm
2.3.4.5§Multi-Door§station§Switcher:§C5-MDS
C5-MDS is used when there are more than one door stations in one block. It serves as a door sta-
tion switcher, to separate video and audio signal for each door station
• 4 door stations can be connected to 1 C5-MDS
• Max. 2 pieces of C5-MDS switchers per block
Parts and Functions
• POWER: Power indicator. Always ON while working.
• LINK: Signal indicator. Flicker means signal is transmitted in bus, always ON means communica-
tion ERROR in bus.
• IN-USE: Status Indicator. ON while working.
• ERROR: Error indication. ON when equipment failure.
• JWB (OUT): Output port. RJ45 port, connected to C5-IPC.