Nortel Networks Sun Fire V100 User Manual
Page 38
NN10287-301 MCS 5100 3.5 Standard 5.0 December 2006
38
Copyright © 2006 Nortel Networks
7
Enter your password: system [Enter]
8
Define server ip address
9
Define server ip subnet mask
10
Define server ip primary gateway address
11
Define port:[Enter]
Note: Type a range [1-18] for every port the Sun Fire V100
server is connected to.
12
Define port for use with SMDI: Define port 19 telnet newline
filtering none
Note: You can verify the ports with the command:show ports
1-19 telnet chara [Enter]
13
Save your changes.
14
Log out.
Note: Using the command define saves the configuration.
15
To kill a session on a port, type: logout port 12 [Enter]
Procedure 9 Connecting a server to the MRV LX terminal server
At the management pc,
1
Connect a cat-5 Ethernet cable from the management PC to the
layer-2 switch.
2
Launch PuTTY.
Note: Refer to the customer-specific information datasheet to
enter the MRV LX terminal server IP address and the port
number.
ATTENTION
The procedures in this document assume that you are using
PuTTY. It is suggested that you download from the web, PuTTY
VT 100 Emulator, a shareware configurator tool to set up
sessions.
Download PuTTY from
http://www.chiark.greenend.org.uk/~sgtatham/putty/