Nortel Networks Sun Fire V100 User Manual
Page 170
![background image](/manuals/192358/170/background.png)
NN10287-301 MCS 5100 3.5 Standard 5.0 December 2006
170
Copyright © 2006 Nortel Networks
The second 120 address should reflect the dmfe0 interface
followed by the hostname concatenated with ‘dmfe0.’
The third 120 address should reflect the dmfe1 interface followed
by the hostname concatenated with ‘dmfe1.’
7
Verify the defaultroute file.
[@mcsappsvr]/export/home/nortel:=> cat
/etc/defaultrouter
120.120.12.1
The only address in this file defines your default gateway route
(your router). If this file is empty and the server is rebooted, you
will not have network access to your other servers.
Sun Fire V240 and Netra 240 H.323 Gatekeeper server verification
The following commands are executed on the Sun Fire V240 or Netra
240 server using PuTTY SSH into the machine logical IP address.
Example: Open a PuTTY SSH session to 120.120.12.31
Procedure 50 Verifying the H.323 Gatekeeper
At the management pc,
1
Log into the server as nortel/
2
After installing the MCS Base Platform System Software CDs
1-6, execute the following command to verify IP addressing.
@mcsappsvr]/export/home/nortel:=> ifconfig -a
lo0:
flags=1000849
mtu 8232 index 1 inet 127.0.0.1 netmask ff000000
bge0:
flags=9040843
120.120.12.32 netmask ffffff00 broadcast 120.120.12.255
groupname imspub
bge0:1:
flags=1000843
broadcast 120.120.12.255
bge1:
flags=69040843