beautypg.com

Nortel Networks Sun Fire V100 User Manual

Page 148

background image

NN10287-301 MCS 5100 3.5 Standard 5.0 December 2006

148

Copyright © 2006 Nortel Networks

Procedure 43 Configuring the iPlanet Monitor

At the System Management Console,

1

Use the values from the table that follows to complete the Web
Monitor tab parameters.

Note: The shaded rows indicate values that must be
addressed by the installer.

Table 41 Web Monitor tab (Sheet 1 of 11)

Parameter

Recommended value

Notes

Example

SNMP request port

8161

default

SNMP agent IP address

Provisioning Module>

192.168.14.41

Active

checked

default

Component Monitoring:
Class name

com.nortelnetworks.i
ms.mw.probe.iplanet.I
planetProcessHandler

default

Component Monitoring:
Component name

Process Stats

default

Component Monitoring:
Polling interval in minutes

1

default

Component Monitoring:
Active for polling

checked

default

Component Monitoring:
Threshold monitors:
Gauge name

percentConnectionQu
eueUsage

default

Component Monitoring:
Threshold monitors:
Upper limit

100

default

Component Monitoring:
Threshold monitors:
Lower Limit

0

default

Component Monitoring:
Threshold monitors:
Negative going threshold
value

10

default