beautypg.com

Siemens SIMATIC NET PROFIBUS User Manual

Page 390

background image

Infrared Link Modul (ILM)

6ZB530–3AC30–0BA1

48

Copyright

by Siemens

Safety

VDE specifications

VDE 0806

=

EN60950 and IEC950

UL/CSA approval

Requirements are met

Climatic environmental conditions

Ambient temperature

0

°

C to

)

60

°

C

(IEC 68–2–1, IEC 68–2–2)

Storage temperature

–40

°

C to

)

70

°

C

(IEC 68–2–14)

Relative humidity

< 95% (none condensing)

(IEC 68–2–30)

If condensation forms on the window, there is a tempo-
rary reduction in the distance that can be covered.
There is no permanent functional disturbance and no
damage to the electronics if the threaded cable inlet ful-
fills the requirements of IP65.

Mechanical environmental conditions

Oscillation during operation

10 to 58 Hz, 0.075 mm deflection

58 to 150 Hz, 10 m/s

2

(1g) acceleration

(IEC 68–2–6)

Oscillation during transportation

5 to 9 Hz, 3.5 mm deflection

9 to 500 Hz, 10m/s

2

(1g) acceleration

Degree of protection

IP 65

Weight

800 g

Dimensions

175

Ч

80

Ч

58 mm

Casing material

Die-cast aluminum

Table 4:

Environmental Conditions for the Use of the PROFIBUS ILM