beautypg.com

8 profibus festoon cable – Siemens SIMATIC NET PROFIBUS User Manual

Page 116

background image

Passive Components for RS-485 Networks

4-18

PROFIBUS Networks SIMATIC NET

6GK1970-5CA20-0AA1 Release 2 05/2000

4.1.8

PROFIBUS Festoon Cable

Fillers

Cores, stranded copper

Cellular PE insulation

Outer sheath of
special PVC

Plastic foil

Copper braid shield

Aluminum foil

Plastic foil

Figure 4-9

Structure of the Festoon Cable

Festoon Cable 6XV1 830-3GH10

The festoon cable 6XV1 830-3GH10 complies with the specification EN 50170,
cable type A, with stranded copper cores (approximately 24 gauge - 19/36) apart
from the higher loop resistance.

This difference means a reduced segment length; refer to the table in Chapter 3
“Notes on Configuration”.

With its flexible structure, the festoon cable 6XV1830-3GH10 can be used in
festoons with large and small cable loops. The cable carries its own weight but is
not suitable for tensile stress > 80 N.

The outer sheath has the identification “SIMATIC NET PROFIBUS RS-485
Festoon Cable 6XV1830-3GH10 * (UL) CMX 75

°

C (SHIELDED) AWG 24” printed

on it along with meter markings.

To help to avoid twisting the cable during installation, the outer sheath has a line
printed along its full length.

If screw terminals are used, the stranded cores must be fitted with wire-end
ferrules (0.25 mm

2

complying with DIN 46228).

The bus connector 6ES7 972-0BA30-0XA0 cannot be connected.

The cable is not suitable for use of the FastConnect (FC) stripping tool.