beautypg.com

7 bus terminals for rs-485 networks, 1 versions – Siemens SIMATIC NET PROFIBUS User Manual

Page 146

background image

Passive Components for RS-485 Networks

4-48

PROFIBUS Networks SIMATIC NET

6GK1970-5CA20-0AA1 Release 2 05/2000

4.7

Bus Terminals for RS-485 Networks

4.7.1

Versions

Overview

A bus terminal is used to attach a single PROFIBUS node with an RS-485
interface to the PROFIBUS LAN cable.

Bus terminals are available in the following versions:

Table 4-9

Versions of the Bus Terminal

Bus terminal RS-485

Bus terminal 12 M

Order no.:

With 1.5 m tap line

6GK1 500-0AA10

With 1.5 m tap line and
additional PG interface

6GK1 500-0DA00

With 3 m tap line

6GK1 500-0AB00

Transmission rate

9.5 Kbps to 1.5 Mbps

9.5 Kbps to 12 Mbps

Power supply

5V / 10 mA
from the node interface

5V / 90 mA
from the node interface

Terminating resistor
combination

integrated, on/off

Integrated, can be activated
with disconnect function

Casing degree of protection

IP20

IP20