Motorola CPCI-6115 User Manual
Page 46
CPCI-6115 CompactPCI Single Board Computer Installation and Use (6806800A68D)
Hardware Preparation and Installation
Installing PMC Modules on the CPCI-6115
44
1. Attach an ESD strap to your wrist. Attach the other end of the ESD strap to the
chassis as a ground. The ESD strap must be secured to your wrist and to ground
throughout the procedure.
2. Remove chassis or system cover(s) as necessary for access to the board.
3. Carefully remove the CPCI-6115 from the card slot and lay it flat, with connectors
J1 through J5 facing you.
4. Remove the PMC filler plate from the front panel of the CPCI-6115.
5. Set the PMC 2 voltage key to the desired position. (The PMC 1 I/O voltage key is
factory-installed at the +5 V position since the IDE controller regulates +5 V I/O. Do
not move the PMC 1 voltage key.)
Personal Injury or Death
Dangerous voltages, capable of causing death, are present in this equipment.
Use extreme caution when handling, testing and adjusting.
+3.3 V
+5 V
PMC Filler Plate
PMC Alignment