Table 2-3, Thermally significant components – Motorola CPCI-6115 User Manual
Page 35
Thermal Requirements
Hardware Preparation and Installation
CPCI-6115 CompactPCI Single Board Computer Installation and Use (6806800A68D)
33
This section provides systems integrators with information that can be used to conduct thermal
evaluations of the board in their specific system configuration. It identifies thermally significant
components and lists the corresponding maximum allowable component operating
temperatures. It also provides sample procedures for component-level temperature
measurements.
summarizes components that exhibit significant temperature rises. These
are the components that should be monitored in order to assess thermal performance. The
table also supplies the component reference designator and the maximum allowable operating
temperature.
You can find components on the board by their reference designators as shown in
. Versions of the board that are not fully populated may not contain some of these
components.
The preferred measurement location for a component may be junction, case or air as specified
in the table. Junction temperature refers to the temperature measured by an on-chip thermal
device. Case temperature refers to the temperature at the top, center surface of the component.
Air temperature refers to the ambient temperature near the component.
Table 2-3 Thermally Significant Components
Component Location
General Description
Maximum
Allowable
Temperature
(Degrees C)
Measurement
Location
(Junction, Case or
Air)
U40
Ultra DMA PCI-IDE
70
° C (158° F)
Air
U36
21555BB PCI Bridge
70
° C (158° F)
Air
U32
MPC7457 Processor
103
° C (217.4° F)
Case
U23, U89
DDR Clock Generator
85
° C (185° F)
Air
U22
MV64360
110
° C (230° F)
Case
U159, U160
32 megabit flash
85
° C (185° F)
Air
U146
Clock Buffer
105
° C (221° F)
Case
U13, U14
Cache
115
° C (239° F)
Case
U2-U10, U74-U82
DDR SDRAM
70
° C (158° F)
Air
U101, U102, U96
Ethernet PHY
120
° C (248° F)
Case