2 setting switches and jumpers, Setting switches and jumpers, Table 2-5 – Motorola CPCI-6115 User Manual
Page 39: Cpci-6115 jumper map
Setting Switches and Jumpers
Hardware Preparation and Installation
CPCI-6115 CompactPCI Single Board Computer Installation and Use (6806800A68D)
37
2.5.2
Setting Switches and Jumpers
illustrates the placement of the switches, jumper headers, connectors
and LED indicators on the CPCI-6115. Use this figure to help identify the approximate location
of the jumpers on the CPCI-6115. There are seven manually configured headers on the
baseboard. They are described in the following table:
Table 2-5 CPCI-6115 Jumper Map
Reference
Function
Comment
J6
Bus Mode Select
Header
Jumper pins 1-2 for 60x mode
Jumper pins 2-3 for MPX mode
J9
Stand-Alone Operation
Header
Jumper pins 1-2 for Stand-Alone operation (no CPCI bus)
J10
Flash Boot Bank Select
Header
No jumper or jumper pins 1-2 for Bank A (32 MB)
Jumper pins 2-3 for Bank B (8 MB)
J15
+/-12 V Present Header
Jumper pins 1-2 allows board operation without +/- 12 V
power
J20
Safe Start ENV Header
No jumper or jumper pins 1-2 for normal ENV settings
Jumper pins 2-3 for safe ENV settings
J25
SROM Initialization
Enable Header
Jumper pins 1-2 to enable SROM init
No jumper or jumper pins 2-3 to disable SROM init
J99
Flash Bank A Write
Protect Header
Jumper pins 1-2 to enable Bank A Flash Write
No jumper to disable Flash Writes
SW2
Manual Geographic
Address -
OFF (default) - GA from CompactPCI backplane
ON - generate address locally
Damage of the Product
Setting/resetting the switches during operation can cause damage of the product.
Check and change switch settings before you install the product.