FUJITSU SPARC ENTERPRISE M9000 User Manual

Page 64

background image

deleteboard(8)

40

SPARC Enterprise Mx000 Servers XSCF Reference Manual • Last Revised August 2009

OPTIONS

The following options are supported.

OPERANDS

The following operand is supported:

-c

disconnect

Detaches the XSB from the domain configuration and keeps it
assigned. If the -c option is omitted, "-c disconnect" is used.

-c

reset

Reserves disconnect of an XSB. If the -c option is omitted, "-c
disconnect

" is used.

-c

unassign

Disconnects the XSB completely from the domain configuration
and puts it in the system board pool. If the -c option is omitted,
"-c disconnect" is used.

-f

Forcibly detaches the specified XSB.

Caution – If the -f option is used to forcibly add a system board
to a domain, all the added hardware resources may not work
normally. For this reason, use of the -f option is not
recommended in normal operation. If the -f option must be
specified, verify the status of every added system board and
device.

-h

Displays usage statement. When used with other options or
operands, an error occurs.

-n

Automatically answers "n" (no) to all prompts.

-q

Suppresses all messages to stdout, including prompts.

-v

Displays a detailed message. If this option is specified with the
-q

option, the -v option is ignored.

-y

Automatically answers "y" (yes) to all prompts.

xsb

Specifies the XSB number to be disconnected. Multiple xsb
operands are permitted, separated by spaces. The following xsb
form is accepted:

x–y

where:

x

An integer from 00–15.

y

An integer from 0–3.