showhardconf(8)
System Administration
395
NAME
showhardconf - display information about field replaceable unit (FRU) installed in
the system
SYNOPSIS
showhardconf
[-u] [-M]
showhardconf
-h
DESCRIPTION
showhardconf
(8) command displays information about each FRU.
The following information is displayed:
■
Current configuration and status
■
Number of installed FRUs
■
Domain information
■
External I/O Expansion Unit information
■
PCI card information
Privileges
You must have one of the following privileges to run this command:
Refer to setprivileges(8) for more information.
OPTIONS
The following options are supported:.
useradm
, platadm, platop, fieldeng
Can run this command for all domains.
domainadm
, domainmgr, domainop
Can run this command only for your accessible domains.
-h
Displays usage statement. When used with other options or
operands, an error occurs.
-M
Displays text by page.
-u
Displays the number of FRUs installed in each unit. In addition,
for CPU modules, the operating frequencies are displayed. For
memory, the DIMM type and size are displayed. If this option is
omitted, the current configuration and status information
regarding FRUs and domain information are displayed.