Restoredefaults – FUJITSU SPARC ENTERPRISE M9000 User Manual
Page 165
restoredefaults(8)
System Administration
141
NAME
restoredefaults - delete the setting and the log information that stored in the server
or the XSCF unit, and restore it to the state as of the factory shipment
SYNOPSIS
restoredefaults
-c range
restoredefaults
-h
DESCRIPTION
The restoredefaults(8) command deletes the setting and the log information
that stored in the server or the XSCF unit, and restores it to the state as of the
factory shipment.
As the range of restoration, one of the following can be specified:
Privileges
You must have platadm privileges to run this command.
Refer to setprivileges(8) for more information.
OPTIONS
The following option is supported:
EXTENDED
DESCRIPTION
In case the restoredefaults(8) command executed to the standby XSCF,
■
when you specify factory, it results in an error;
■
when you specify xscfu, only the standby XSCF will be initialized.
XSCF unit (xscfu)
Restores the following information in XSCF unit to the state as of the factory
shipment:
■
Various setting information in XSCF
■
Log information that stored in XSCF unit
■
Backup information of operator panel
server (factory)
Restores the setting and the log information that stored in operator panel and
XSCF unit to the state as of the factory shipment.
-c
range
Specifies the target of restoration. In range, one of the following
values can be specified:
xscfu
Restores the XSCF unit.
factory
Restores the server.
-h
Displays usage statement. When used with other options or
operands, an error occurs.