Showdualpowerfeed – FUJITSU SPARC ENTERPRISE M9000 User Manual

Page 407

background image

showdualpowerfeed(8)

System Administration

383

NAME

showdualpowerfeed - display the current setting of dual power feed mode

SYNOPSIS

showdualpowerfeed

showdualpowerfeed

-h

DESCRIPTION

The showdualpowerfeed(8) command displays the current setting of dual power
feed mode in the system.

Note – The ability to display the current status of the dual power feed is available
on M3000/M4000/M5000 servers only. However, the dual power feed mode cannot
be used with 100V power on M4000/M5000 servers. When the optional power
cabinet for dual power feed is connected on M8000/M9000 servers, it automatically
configures the dual power feed mode. For details about the setting the dual power
feed, see the Installation Guide for your server.

The dual power feed mode can be set by the setdualpowerfeed(8) command.
Also, before the dual power feed mode is changed by the setdualpowerfeed(8)
command, the values of changed settings are displayed.

Privileges

You must have platadm or fieldeng privileges to run this command.

Refer to setprivileges(8) for more information.

OPTIONS

The following options are supported:

EXAMPLES

EXAMPLE 1

Displays the current setting of dual power feed mode in the system.

EXAMPLE 2

Changes the dual power feed mode with the setdualpowerfeed(8) com-
mand and then displays the current state.

EXIT STATUS

The following exit values are returned:

-h

Displays usage statement.

XSCF>

showdualpowerfeed

Dual power feed is enabled.

XSCF>

showdualpowerfeed

enable -> disable

NOTE: Dual power feed will be disabled the next time the platform is powered
on.

0

Successful completion.

>0

An error occurred.