ioxadm(8)

88

SPARC Enterprise Mx000 Servers XSCF Reference Manual • Last Revised April 2010

OPTIONS

The following options are supported.

-f

Forces command execution by ignoring warnings.

-h

Displays usage statement.

When used with other options or operands, an error occurs.

-M

Displays text by page.

-p

Displays only parsable output, suppressing headers in that output.
Fields are separated by single tabs.

-v

Displays verbose output. Refer to specific operands for details.

target

Specifies the target device, which can be a card mounted in a built-
in PCI slot in the host system; an External I/O Expansion Unit; or a
field replaceable unit (FRU) in an External I/O Expansion Unit.

The card in the host slot is identified by the host_path to the card.

host_path is platform dependent and indicates the path to the
slot on the host system that contains the card. The host_path has
the following format:

IOU#0-PCI#0 IO Board 0, PCI-E slot0

The External I/O Expansion Unit (box_id) is identified by serial
number.

Use iox@nnnn, where nnnn represents the last four digits of the
box serial number.

Some commands affect only a single component of an External
I/O Expansion Unit system. For example, individual boats and
power supplies can be turned on and turned off independently.

A FRU in an External I/O Expansion Unit (fru) is identified as:

iox@nnnn/iob0

– I/O boat in the left tray (rear view)

iox@nnnn/iob1

– I/O boat in the right tray (rear view)

iox@nnnn/iob0/link

– Uplink card in boat 0

iox@nnnn/iob1/link

– Uplink card in boat 1

iox@nnnn/ps0

– Power supply in the left bay (front view)

iox@nnnn/ps1

– Power supply in the right bay (front view)