beautypg.com

FUJITSU SPARC ENTERPRISE M9000 User Manual

Page 420

background image

showhardconf(8)

396

SPARC Enterprise Mx000 Servers XSCF Reference Manual • Last Revised April 2010

EXTENDED

DESCRIPTION

When the configuration and status information regarding FRUs and domain
information are displayed, for any failed or degraded unit, an asterisk (*)
indicating an abnormal unit is displayed along with any of the following states:

On the Type field of the memories, the number indicates the DIMM size and the
alphabet, A or B, indicates the DIMM rank.

EXAMPLES

EXAMPLE 1

Displays the information of the FRUs in the M5000 server.

Status

Description

Faulted

The component is faulty and is not operating

Degraded

The component is operating. However, either an error has been
detected or the component is faulty. As a result, the component
might be operating with reduced functionality or performance.

Deconfigured

As a result of another component's faulted or degraded status,
the component is not operating. (The component itself is not
faulted or degraded.)

Maintenance

The component is under maintenance. A deletefru(8),
replacefru

(8), or addfru(8) operation is currently underway

Normal

It is operating normally.

Example

Description

Type: 1A

1 GB, rank 1

Type: 2A

2 GB, rank 1

Type: 2B

2 GB, rank 2

XSCF>

showhardconf

SPARC Enterprise M5000;

+ Serial:BCF07500B6; Operator_Panel_Switch:Locked;

+ Power_Supply_System:Dual; SCF-ID:XSCF#0;

+ System_Power:On; System_Phase:Cabinet Power On;

Domain#0 Domain_Status:Initialization Phase;

Domain#1 Domain_Status:Initialization Phase;

MBU_B Status:Normal; Ver:0201h; Serial:BC07490823 ;

+ FRU-Part-Number:CF00541-0478 05 /541-0478-05 ;

+ Memory_Size:64 GB;