FUJITSU SPARC ENTERPRISE M9000 User Manual
Page 420
showhardconf(8)
396
SPARC Enterprise Mx000 Servers XSCF Reference Manual • Last Revised April 2010
EXTENDED
DESCRIPTION
■
When the configuration and status information regarding FRUs and domain
information are displayed, for any failed or degraded unit, an asterisk (*)
indicating an abnormal unit is displayed along with any of the following states:
■
On the Type field of the memories, the number indicates the DIMM size and the
alphabet, A or B, indicates the DIMM rank.
EXAMPLES
EXAMPLE 1
Displays the information of the FRUs in the M5000 server.
Status
Description
Faulted
The component is faulty and is not operating
Degraded
The component is operating. However, either an error has been
detected or the component is faulty. As a result, the component
might be operating with reduced functionality or performance.
Deconfigured
As a result of another component's faulted or degraded status,
the component is not operating. (The component itself is not
faulted or degraded.)
Maintenance
The component is under maintenance. A deletefru(8),
replacefru
(8), or addfru(8) operation is currently underway
Normal
It is operating normally.
Example
Description
Type: 1A
1 GB, rank 1
Type: 2A
2 GB, rank 1
Type: 2B
2 GB, rank 2
XSCF>
showhardconf
SPARC Enterprise M5000;
+ Serial:BCF07500B6; Operator_Panel_Switch:Locked;
+ Power_Supply_System:Dual; SCF-ID:XSCF#0;
+ System_Power:On; System_Phase:Cabinet Power On;
Domain#0 Domain_Status:Initialization Phase;
Domain#1 Domain_Status:Initialization Phase;
MBU_B Status:Normal; Ver:0201h; Serial:BC07490823 ;
+ FRU-Part-Number:CF00541-0478 05 /541-0478-05 ;
+ Memory_Size:64 GB;