beautypg.com

Setdualpowerfeed – FUJITSU SPARC ENTERPRISE M9000 User Manual

Page 225

background image

setdualpowerfeed(8)

System Administration

201

NAME

setdualpowerfeed - set dual power feed mode

SYNOPSIS

setdualpowerfeed

-s key

setdualpowerfeed

-h

DESCRIPTION

The setdualpowerfeed(8) command specifies dual power feed mode in the
system.

Note – The ability to enable and disable dual power feed is available on M3000/
M4000/M5000 servers only. However, dual power feed mode cannot be used with
100V power on M4000/M5000 servers. When the optional power cabinet for dual
power feed is connected on M8000/M9000 servers, it automatically configures dual
power feed mode. For details about the setting of dual power feed, see the
Installation Guide for your server.

To enable the dual power feed mode, you need to execute the rebootxscf(8)
command or turn off and on the input power.

To disable the dual power feed mode, you need to turn off and on the input power.

Privileges

You must have platadm or fieldeng privileges to run this command.

Refer to setprivileges(8) for more information.

OPTIONS

The following options are supported:

EXTENDED

DESCRIPTION

The state of the current dual power feed mode can be checked by using the
showdualpowerfeed

(8) command.

EXAMPLES

EXAMPLE 1

Disables dual power feed mode in the system. Before rebooting the system, a
message is displayed.

-h

Displays usage statement. When used with other options or
operands, an error occurs.

-s

key

Sets dual power feed mode in the system. Either of the following
can be specified for key:

enable

Enables the dual power feed mode.

disable

Disables dual power feed mode.

XSCF>

setdualpowerfeed -s disable

enable -> disable

NOTE: Dual power feed will be disabled the next time the platform is powered
on.