showlocator(8)
System Administration
421
NAME
showlocator - display the state of the CHECK LED on the operator panel
SYNOPSIS
showlocator
showlocator
-h
DESCRIPTION
showlocator
(8) command displays the blink state of the CHECK LED on the
operator panel.
The one of the following state is displayed:
Privileges
You must have one of the following privileges to run this command:
useradm
, platadm, platop, fieldeng
Refer to setprivileges(8) for more information.
OPTIONS
The following option is supported:
EXTENDED
DESCRIPTION
The setlocator(8) command can be used to specify the blink state of the CHECK
LED.
EXAMPLES
EXAMPLE 1
Displays the CHECK LED state.
EXIT STATUS
The following exit values are returned:
SEE ALSO
setlocator(8)
Off
Indicates normal operation, which means either the circuit
breaker is off or power is not being supplied.
Blinking
Indicates that the unit is a maintenance target.
On
Indicates that an error was detected in the main unit.
-h
Displays usage statement.
XSCF>
showlocator
Locator LED status:Blinking
0
Successful completion.
>0
An error occurred.