cfgdevice(8)

32

SPARC Enterprise Mx000 Servers XSCF Reference Manual • Last Revised September 2008

EXAMPLES

EXAMPLE 1

When the system is being powered off, reserves the connection of the

CD-

RW/DVD-RW drive unit and the tape drive unit

to the port 0-0.

EXAMPLE 2

When the system is being powered on, connects the

CD-RW/DVD-RW

drive unit and the tape drive unit

to port 0-0.

EXAMPLE 3

Disconnects the

CD-RW/DVD-RW drive unit and the tape drive unit

from

the port 0-0.

EXAMPLE 4

Displays the status of individual

CD-RW/DVD-RW drive unit and the tape

drive unit

set on the M8000 server and the M9000 server without the expan-

sion cabinet.

EXAMPLE 5

Displays the status of individual

CD-RW/DVD-RW drive unit and the tape

8-2 disable down enable up

8-4 disable down enable up

8-6 disable down enable up

XSCF>

cfgdevice -c attach -p 0-0

Are you sure you want to attach the device [y|n] :

y

Completed.( Reservation )

XSCF>

cfgdevice -c attach -p 0-0

Are you sure you want to attach the device [y|n] :

y

Completed.

XSCF>

cfgdevice -f -c detach -p 0-0

Are you sure you want to detach the device [y|n] :

y

Completed.

XSCF>

cfgdevice -l

Current connection for DVD/DAT: port 0-0

Expander status

Port No. IOU/SAS-status SAS-status

-----------------------------------

0-0 enable up enable up

0-2 disable down enable up