beautypg.com

FUJITSU SPARC ENTERPRISE M9000 User Manual

Page 54

background image

cfgdevice(8)

30

SPARC Enterprise Mx000 Servers XSCF Reference Manual • Last Revised September 2008

Privileges

You must have platadm or fieldeng privileges to run this command.

Refer to setprivileges(8) for more information.

OPTIONS

The following options are supported:

EXTENDED

DESCRIPTION

When the command is executed, a prompt to confirm execution of the command
with the specified options is displayed. Enter "y" to execute the command or "n"
to cancel the command.

SAS-status

Connection status between I/O unit and the system.

enable/disable

: Connection setting between I/O unit and

the system. When starting a domain with no I/O unit, the
"disable" may be displayed.

enable

: Yes

disable

: No

up/down

: Logical connection between I/O unit and the

system.

up

: Connected.

down

: Not connected.

-c

attach

Connects the CD-RW/DVD-RW drive unit and the tape drive
unit to the specified port.

-c

detach

Disconnects the CD-RW/DVD-RW drive unit and the tape
drive unit from the specified port.

-h

Displays usage statement. When used with other options or
operands, an error occurs.

-l

Displays the current status of the CD-RW/DVD-RW drive
unit and the tape drive unit currently set up.

-M

Displays text by page. This option provides a function that is
the same as that of the more command.

-n

Automatically answers "n" (no) to all prompts.

-p

port_no

Specifies the number of the port, in the specified domain, to
which the CD-RW/DVD-RW drive unit and the tape drive
unit is to be connected. port_no can be specified in the ’IOU
number
-PCI slot number’ format. The -p option cannot be
omitted.

-q

Suppresses all messages to stdout, including prompts.

-y

Automatically answers "y" (yes) to all prompts.