beautypg.com

5 technical data, Technical data – FUJITSU PRIMERGY BX400 S1 User Manual

Page 25

background image

BX400 S1

Operating Manual

25

Introduction

1.5

Technical data

Electrical data (hot-plug power supply unit)

Compliance with regulations and standards

Rated voltage range

100 - 120 V / 200 - 240 V

Frequency 50 Hz-60 Hz
Max. rated current

45 A (100 - 120 V) /
22.5 A (200 - 240 V)

Effective power

1785 W (240 V) 1200 W (100 V)

Apparent power

1821 VA (240 V) 1265 VA (100 V)

Heat dissipation

6426 kJ/h (with 1785 W) 4320 kJ/h
(with 1200 W)

Main power fuse

16 A

Protection class

I

Product safety and
ergonomics

IEC 60950-1 / EN 60950-1, UL/CSA 60950-1 (all
second edition is acquired)
CNS 14336 / GB 4943 / EN 50371

Electromagnetic
compatibility

GB 17625

interference
emissions

EN 55022 class A

Harmonic current EN 61000-3-2
Flicker

EN 61000-3-3

interference
immunity

EN 55024, EN 300386

to EU directives

Electromagnetic compatibility 2004/108/EC

Mechanical
environmental
conditions

EN 60721-3-3; class 3M2