beautypg.com

Interface information data transmission timing, User's manual d-6 – FUJITSU DL3800 User Manual

Page 218

background image

User's Manual

D-6

INTERFACE INFORMATION

Data Transmission Timing

In unidirectional mode (conventional Centronics interface), this
printer guarantees the received data when the Data and Data Strobe
signals from the computer have the following timing with respect to
the Busy and Acknowledge signals from the printer.

T5

T6

T1, T2, T3 > 1 µs
T4 < 1 µs
0 µs < T5 < 3 µs
2 µs < T6 < 6 µs

T1

Data 1 to Data 8

Data Strobe

BUSY

Acknowledge

T2

T3

T4

In bidirectional mode (nibblemode), this printer can send data to the
computer. Data is sent in units of four bits (nibble) using four output
signal lines as data paths. The following outlines one byte of data sent
during reverse data transfer phase in nibble mode.

Data Available (*)

X Flag

Ack Data Req

Printer Busy

Host Busy

(from CPU)

Printer Clock

Data bit 4

Data bit 5

Data bit 6

Data bit 7

Data bit 0

Data bit 1

Data bit 2

Data bit 3

1284 Active

(from CPU)

* Data Available is assigned for the cable.

#D Appendix D

2000.09.20, 2:47 PM

6