7 analog application example - t-1 primary clock, Analog connectivity – Torso Electronics T-1 16-Track Algorithmic Desktop Sequencer User Manual
Page 201
201
The T-1 Notebook : Reference & Guide
Analog Connectivity
9
9.7 Analog Application Example - T-1 Primary Clock
T-1 can operate as the primary clock device in a setup where other devices will follow. This is a
common configuration. Matching up the clock pulses and run signals is important to ensure the right
tempo synchronisation. Analog synchronisation options can be edited in the T-1 Config tool.
Example Configuration: T-1 with ALM Pam’s New Workout - PNW Eurorack Module
clk
Sync Out
rst
Sync Out
Patch Cables
Eurorack + PNW Environment
Pam’s New Workout synchronised as the secondary follower to T-1 as the
primary clock. Any connected devices to PNW will be synchronised.
T-1 as the primary clock. Any connected devices, i.e PNW will be synchronised.
Pam’s New Workout default key settings:
•
PPQN = 24 - Matches T-1
•
Run? = Set to Y, i.e. Yes. To allow a run input rather
than automatic start on sensing a clock signal. This is
a more accurate configuration. T-1 Run set to give a
gate high for play and low for stop.
T-1 Environment
Tempo will follow T-1
50%
24 PPQN
reset
reset
run
run
24 PPQN
Analog Clock
Analog Reset
Rate
Pulse width
In
In
Out
Out