9.5 Analog Synchronisation
The Analog synchronisation options can be edited in the T-1 Config tool.
These are based on the analog clock settings. The analog clock is the
highest function in the clock hierarchy, followed by MIDI than Link comes
last. If multiple clocks are connected to T-1 the hierarchy dictates the
primary lead clock used.
199
The T-1 Notebook : Reference & Guide
NOTES
Analog Connectivity
9
The rate should be matched to the external device. The speed of the sequences
may be out of synchronisation i.e. Tempo if the clock rate is not matched. Try
different settings to synchronise but check manufacturers documentation first. The
pulse width can be set between 15% and 85%. The default of 50% should be ok for
most circumstances but this can be adjusted if there are issues recognising the
clock from other devices.
The input and output labelled sync in and sync out ‘rst’ has two behavioural options
to select from:-
Reset:
Will trigger a reset pulse when the
pattern starts. This is default state.
Pattern Start
Play
Stop
Run:
Gate signal. Gate high when T-1 is
playing. Gate low when stopped.
50%
24 PPQN
reset
reset
run
run
24 PPQN
Analog Clock
Analog Reset
Rate
Pulse width
In
In
Out
Out
1
2
3
Clock Sync Hierarchy
T1 System
Analog Clock
MIDI Clock
Link
Sync In - Clk
MIDI In
Ableton Link WiFi
Analog Clock Sync
Rate & Pulse width