beautypg.com

Main_dac immediate registers, Main_dac triggered registers – HP E1418A User Manual

Page 139

background image

Notes

Each incremental value of the A24 Window offsets the window by 32 bytes.
Up to 512 bytes of A24 space can be pointed to.

A24 Window values 8

16

through F

16

point to Calibration Registers.

Calibration Registers 00100

16

through 001BE

16

are located in non-volatile

(FLASH) memory. Writing to this memory requires a complicated sequence
of register accesses not documented here. It is recommended that calibration
be performed using the SCPI driver for the module, not register access.

Main_DAC

Immediate

Registers

The Main_DAC Immediate Registers are used to program the next output
value on a channel. There are 16 registers, one for each output channel. The
register at base + 40

16

programs channel 1, base + 42

16

programs channel 2,

up to base +5E

16

to program channel 16. Values loaded in these registers are

applied to the output immediately (no trigger condition is required).

Address

Base + 40

16

through

Base + 5E

16

Bit

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

00

WRITE

Output Value

Output Value: Writing a 16-bit value to this field outputs the value on the
channel selected by the base address. The 16-bit value is a 2’s complement
number. Scaling is based upon 16 V maximum for voltage mode and .020
Amps for current mode.

Main_DAC

Triggered Registers

The Main_DAC Triggered Registers are used to program the next output
value on a channel. There are 16 registers, one for each output channel.
The register at base + 60

16

programs channel 1, base + 62

16

programs

channel 2, up to base +7E

16

to program channel 16. Values loaded in these

registers are applied to the output(s) following the next trigger event.

Address

Base + 60

16

through

Base + 7E

16

Bit

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

00

WRITE

Output Value

Output Value: Writing a 16-bit value to this field outputs the value on the
channel selected by the base address. The 16-bit value is a 2’s complement
number. Scaling is based upon 16 V maximum for voltage mode and
.020 Amps for current mode.

138 HP E1418A Register-Based Programming

Appendix B

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com