beautypg.com

Reset and registers – HP E1418A User Manual

Page 120

background image

Reset and Registers

Following power-on or a

*RST

command, the registers are put into the

following states:

The Manufacturer ID and Device ID Registers remain unaffected.

The Channel Mode Register (base + 1A

16

) is set to voltage output

for all channels (FFFF

16

) or is set to the state set by the V/I jumper

(described on page 31) if the P/J jumper is in the jumper selectable
position.

The Channel Program Jumper Register (base + 16

16

) is set to program

selectable for all channels (FFFF

16

) or to the position of the P/J jumper

(described on page 31).

The Channel Relay Control Register (base + 1C

16

) is set to open all

channel relays (FFFF

16

).

The Isolation Status Register (base + 14

16

) reflects the isolated/

non-isolated configuration of each channel.

The Calibration Control Register (base +08

16

) is set to calibrate

voltage with the cal mux disabled (2000

16

).

Channel Trigger Register (base + 18

16

) is set to 0000

16

if the

module is a 16-channel configuration or FF00

16

if an 8-channel

configuration.

Note

The upper 8-bits of all channel related registers are set to 1’s (FF

16

) for

8-channel configurations.

Appendix B

HP E1418A Register-Based Programming 119

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com