Changing the settings – Pioneer Toraiz SQUID - Creative Multitrack Sequencer User Manual
Page 130
Changing the settings
130
En
•
24ppqn:
Timing clock rate of 24ppqn (Pulse Per Quarter Note)
24 pulse of the input timing clock is counted as the length of one
quarter note.
•
48ppqn:
Timing clock rate of 48ppqn (Pulse Per Quarter Note)
48 pulse of the input timing clock is counted as the length of one
quarter note.
•
Gate:
Gate input of V-Trigger. Up to 12 V voltage can be input.
A pattern plays while the Gate signal is being input and pauses while
no Gate signal is being input. If the Gate signal is input while the
sequence pattern is in the stopping state, the sequence pattern
playback will start from the first step.
– When you use the
[CLOCK IN]
terminal as the Gate input, select a
terminal other than the
[CLOCK IN]
terminal for a master clock
source.
Notes
• [GATE]
corresponds to V-Trigger only.
•
When
[Gate]
is selected, sequence playback/stop cannot be
controlled by inputting the Start/Stop signals to the
[CLOCK IN]
terminal.
•
For Audio Trigger input, select from
[1step]
,
[1ppqn]
,
[2ppqn]
, or
[4ppqn]
.
•
If you change a setting value during sequence playback, the
sequence playback stops.