beautypg.com

Horizontal, Horizontal -14 – RIGOL MSO/DS2000A Series User Manual

Page 42

background image

RIGOL

Chapter 1 Quick Start

1-14

MSO2000A/DS2000A User’s Guide

HORIZONTAL

MENU: press this key to open the

horizontal control menu under which
you can turn on or off the delayed
sweep function, switch between
different time base modes, switch
between

“Coarse” and “Fine” adjustment of scale as well as modify the horizontal reference
setting.

HORIZONTAL SCALE: modify the horizontal time base. Turn clockwise to
reduce the time base and turn counterclockwise to increase. During the
modification, waveforms of all the channels will be displayed in expanded or
compressed mode and the time base message (e.g.

) at the upper side of

the screen would change accordingly. Press down this knob to quickly switch to the
delayed sweep state.

HORIZONTAL POSITION: modify the horizontal position. The trigger point
would move left or right relative to the center of the screen when you turn the knob.
During the modification, waveforms of all the channels would move left or right and
the trigger position message (e.g.

) at the upper-right corner of the

screen would change accordingly. Press down this knob to quickly reset the trigger
position (or the delayed sweep position).