RIGOL MSO/DS2000A Series User Manual
Page 241
RIGOL
MSO2000A/DS2000A User’s Guide
13-17
two points and create a ladder-like waveform.
2. Zoom
Press Zoom to turn on or off the zoom function.
ON: the waveform editing window only displays the current point.
OFF: the waveform editing window displays all the initial points.
3. Current Point
Press Current and use
or the navigation knob to select the point to be
edited. The range is from 1 to the initial points. For the setting method, please
refer to the introduction in “Parameter Setting Method”.
4. Voltage
Press Voltage and use
or the navigation knob to set the voltage of the
current point. The range is from -2.5 V to +2.5 V. For the setting method, please
refer to the introduction in “Parameter Setting Method”.
5. Time
Press Time and use
or the navigation knob to set the duration of the
current point. This setting is limited by the times of the previous point and
following point. The time of point 1 is fixed at 0 s. For the setting method, please
refer to the introduction in “Parameter Setting Method”.
6. Insert
Press Insert to insert a new waveform point between the current point and the
next point.
7. Delete
Press Delete to delete the current point from the waveform and connect the
remaining points using the current interpolation mode.
Note:
Point 1 cannot be deleted.
8. Done
Press Done to finish editing the current waveform.
9. Save
Press Save to enter the file store interface. Please refer to the introduction in