beautypg.com

RIGOL MSO/DS2000A Series User Manual

Page 198

background image

RIGOL

Chapter 8 Protocol Decoding

8-20

MSO2000A/DS2000A User’s Guide

8. Decoded CAN Data Interpretation

 Frame ID: displayed as hex digits in blue.
 Data Length code (DLC): displayed as a chartreuse patch.
 Data Frame: displayed as green patches if data is successfully decoded. The

frames appear as red patches if the data frame is lost.

 Cyclic Redundancy Check (CRC): displayed in a light blue patch when valid

and red error mark is displayed when error occurs.

Figure 8-17 Decoded CAN Data Interpretation

Address ID Data Length Data CRC Check Error