beautypg.com

RIGOL MSO/DS2000A Series User Manual

Page 144

background image

RIGOL

Chapter 6 MATH and Measurements

6-8

MSO2000A/DS2000A User’s Guide

Press MATHOperate to select “Logic”:
 Press Formula to select the desired logic formula and the default is “AND”.
 Press Source A and Source B to select the desired channels (CH1, CH2 or any

channel of D0-D15).

 Press

and use

to adjust the vertical position of the operation results.

 Press

and use

to adjust the vertical scale of the operation results.

 Press Invert to turn the inverted display of the operation results on or off.
 Press Threshold A and use

to set the threshold of source A in logic

operation.

 Press Threshold B and use

to set the threshold of source B in logic

operation.

Note:

When Source A or Source B is set to any channel of D0-D15,

Threshold A or Threshold B will be hidden automatically and cannot be set.

 Press Label to define a label for the operation results. For the details, please

refer to

MATH Label.

HORIZONTAL POSITION and HORIZONTAL SCALE can also be

used to adjust the horizontal position and scale of the operation results.