beautypg.com

2 servopack (1) installation – Yaskawa i80M Connecting Manual User Manual

Page 322

background image

2.2 Servopack

(1) Installation

The Servopack type

is mounted on the base as standard.

(2) Location

When installed in a panel :

Keep the temperature around Servopack at

or below. (Fig.

3)

When installed near a heat source:

Keep the temperature around Servopack below 55°C. (Fig.

4)

If subjected to vibration:

Mount the unit on shock absorbing material.

If corrosive gases are present:

Avoid locations where corrosive gases exist as it may cause extensive damage over long

use.
Especially vulnerable are switching operation of contractors and relays.

Unfavorable atmospheric conditions:

Select a location with minimum exposure to oil, water, hot air, high humidity, excessive dust
or metallic particles.

EXHAUSTED AIR

55°C OR

I

BELOW

1

PANEL

Servopack

H EAT

SOURCE

/

___

- - -

SHIELD

Fig. A8. 3 Typical Layout

Panel Mounting

Fig.

4 Protection against Heat Radiation

(3) Mounting Direction

Mount the unit vertically on the wall using the mounting holes (4) on the base plate, with main

terminals at the bottom. (Fig. A8. 5)

VERTICAL MOUNTING

HORIZONTAL MOUNTING

TOP

HEAT SINK

HEAT SINK

WALL

lCN

, TERMINAL /

TERMINAL BOTTOM

lCN

Good

Poor

Poor

Fig. A8. 5 Mounting Direction of Servopack

322