Page 256
21.3.1.26
CURRENT VALUE STORAGE INPUT
(
PST
# 3 0 0 8 3 )
This input is used to store the current values into the control memory.
When the PST input closes, the control stores the current values into the internal memory.
The offset data written by the MDI are later operated
offset memory.
Data written
Input data
—
into offset memory
I
I
on as follows and then stored into the
Current value data
stored in
control memory
When the reset procedure (turning ON the MDI panel reset key or closing the external reset
input) is performed, the current value storage mode is canceled with LED blinking terminated.
NOTE
The current value storage position and procedure and offset memory
storage value computations vary with the machine.
21. 3. 1. 27
These inputs
EXTERNAL STORAGE, EXTERNAL VERIFICATION, EXTERNAL OUTPUT, AND
EXTERNAL CLEAR SIGNAL INPUTS (EIN # 30110, EVER # 30111, EOUT # 30112,
ECLM # 301 13)
are used to externally perform the storage, verification, output, or clear operation
relative to the control NC memory.
When the inputs are closed, the following operations are performed.
(When the EIN input is closed)
Part programs are stored into NC memory.
(When the EVER input is closed)
Part programs are compared against NC memory.
(When the EOUT input is closed)
The contents of NC memory are output.
(When the ECLM input is closed)
The contents of the NC memory are cleared.
While the above storage, verification, output, or clear operation is being performed, the editing
state
output is closed.
NOTE
The storage/verification 1/0 equipment varies with the setting (#0009).
256