(2) SERVO UNIT

Total

Servo Unit

H e a t

i

Internal Heat Value (W)

R e g e n e r a t i v e

Resistance

Value ‘

(w)

100% Load Factor

Load Factor

50% Load Factor

(w)

70

50

100

58

110

61

130

70

140

73

65

60

60–100

220

97

82

71

80–120

IR44SB

270

112

92

79

100–140

NOTE :

1 ) The internal heat

the heat

remaining insid

e

cabinet

th

e

fi

n

posed outside the cabinet and the outside air of more than 2.5 m/s blows

the fin.

2) In designing

cabinet contain the servo

the load factor differs depending

the specifications

of the machine, hut the load factor of 70% is considered normal.

3)

heat value of the regenerative resistance

depending on the operating conditions.

4.4

DUST-PROOF CONSTRUCTION

Particles floating in the air (dust, cuttings, oil mist, etc.) may cause malfunction of the CPU mod-
ule and the inner parts of the other boards (particularly CRT) to be mounted inside the cabinets

the machine manufacturers design and build.

The construction of the cabinets, therefore,

should be such that it does not allow dust, etc. to enter inside.

The cabinets should be of totally-enclosed construction.

(2) Seal the cable openings with packing. (See Fig. 4. 5.)

The door and the back cover should be securely sealed with packing. (See Fig. 4. 6.)

(4) Special caution is required for the CRT unit as it operates at high voltage and collects dust

in the air.

The following points should be observed with regard to the pendant box used to

install the CRT unit.

(a) Seal the cable openings, door, back cover, etc. with packing to eliminate gap,

(b)

Packing is attached on the surface where the CRT unit is to be mounted. Use the pen-

dant box as it is.

(5) Seal all gaps.

(6) Oil mist easily settles on the ceiling and enters the cabinets through screw holes. Special

precaution, therefore, should be made using oil-proof packing, etc.

12