Yaskawa i80M Connecting Manual User Manual
Page 157

20.2.40 DIRECTPROC
E
SSING SIGNALMONITOR OU
TP
UTS (
H
lNl#35l4O-Hl
N
3 #35142)
The direct processing signal monitor outputs represent the status of the direct IN signals
which are directly read from
FC
230
B
circuit board connector CN26 to the NC.
20.10 Relationship between Direct IN Signals and Direct
Processing Signal Monitor Outputs
20.2.41 POSITIONING COMPLETION (DEN #35374) OUTPUTS
These outputs inform the completion of a move command when an M/S/T or B command and
the move command have been specified in the same block at the execution of part program in
the automatic operation mode.
The block in which an M/S/T or B command and a move command are specified at the same
time is executed, if the M/S/T or B command is not completed at the termination of the move
command positioning, completion output DEN is closed.
When FIN input is closed then opened and the M/S/T or B command is completed, the posi-
tioning completion outputs are opened.
20.2.42 ON OPERATION (OP #35357) OUTPUTS
This output is generated at the beginning of automatic operations to indicate that the control is
operating. The “ON OPERATION” output
is closed when the machine starts. It turns
OFF upon reset (including the reset caused by M02 or
This output is generated only
while the GO1 or GOO operation is conducted in the automatic operation mode.
20.2.43 CANNED CYCLE OPERATION STATE MONITOR OUTPUT
# 35390, G84s
# 35391, TAP # 35392)
When canned cycles are being performed, the following monitor signal will be sent out.
The spindle is controlled by M code during canned cycles.
(1) Canned Cycles
The canned cycles signal
output is generated within 8 ms after the beginning of canned
cycle, The canned cycle signal is turned OFF by the canned cycle cancellation block.
Fig.
Canned Cycle Signal
157