9.2 PARAMETER NUMBER TABLE (Cent’d)
Parameter No.
N A M E
MVILK5 MVILK4 MVILK3
(Bit No,
6
5
4
3
2
1
O : Alarm not set when move command other than G28
is executed without once conducting manual or auto
reference point return after turning on the 5th axis
power supply.
1: Alarm set when move command other than G28 is
executed without once conducting manual or auto
reference point return after turning on the 5th axis
power supply,
MVILK4
0
: Alarm not set when a move command other than G28
is executed without once conducting manual or auto
reference point return after the 4th axis power is
turned on.
1 : Alarm set when a move command other than G28 is
executed without once conducting manual or auto
reference point return after the 4th axis power supply
is turned on.
O : Alarm not set when a move command other than G28
is executed without once conducting manual or auto
reference point return after turning on the Z-axis
power supply.
1: Alarm set if a move command other than G28 is
executed without once conducting manual or auto
reference point return after turning on the Z-axis
power supply.
O : Alarm not set if a move command other than G28 is
executed without once conducting manual or automatic
reference point return after turning on the Y-axis
power supply.
1: Alarm set if a move command other than G28 is
executed without once conducting manual and auto
reference point return after turning. on the Y-axis
power supply.
O : Alarm not set when a move command other than G28
without once conducting manual or auto referent pent
return after turning on the X-axis power supply.
1: Set alarm when a move command other than G28 is
executed without once conducting manual or auto
reference point return after turning on the X-axis
power supply.