8.14.4 Parameter 65001 operating status parameter structure

This parameter structure is a read only structure where

information on the Encoder operating status can be found. It is a

complement to the PROFIdrive parameter 979 described in the

Profile for Drive Technology, PROFIdrive V4.1, order nr 3.172

available from PROFIBUS and PROFINET International.

PNU

65001

Significance

Encoder operating status

Data type

Array[n] Integer32

Access

Read

Validity range

Profile specific

Explanation

The operating status displays the status of the encoder.

Table 51

Structure of 65001 Encoder operating status

Sub index

Meaning

Note/limitations

0

Header

1

Operating status

2

Faults

3

Supported Faults

4

Warnings

5

Supported warnings

6

Encoder profile version

7

Operating time

Only supported in DPV1 for

the encoder gateway and the

absolute encoder

8

Offset value

9

Measuring units per revolution

10

Total measuring range in measuring

units

11

Velocity measuring unit

Only supported in DPV1 for

the encoder gateway

Table 52

Detailed structure of 65001 Operating status