Absolute encoder installation

23

Encoders equipped with cable glands are delivered with a dust

protection foil from the factory. The protection foil needs to be

removed prior to install the cables.

It is recommended that encoders with cable gland are equipped

with a shielded power supply cable with conductor area between

0,34 mm

2

to 1.5 mm

2

. Permissible outer cable diameter is

ø 6 mm to ø 8 mm for the power supply cable. Located inside the

back cover are two screw terminals containing the required power

supply terminals marked (+) and (-). In the case were the encoder

is the last node in the bus-structure and only the cable glands for

Supply and Bus-in is in use, the Bus out cable gland should be

replaced with a M16 filler plug to ensure proper sealing.

The (+) terminal shall be used to connect the +EV-line (9-36 Vdc).

The (-) terminal shall be used to connect the 0 V-line.

Figure 8

Terminal connections of power supply cables

Note: Tighten all screws in the terminal, even if no cable has

been attached.