7.4.10 Parameter 980, read only
This parameter shows the supported parameters
980 unsigned int
980[0] = 918
980[8] = 979
980[16] = 65002
980[1] = 922
980[9] = 61000
980[17] = 65003
980[2] = 925
980[10] = 61001
980[3] = 964
980[11] = 61002
980[4] = 965
980[12] = 61003
980[5] = 971
980[13] = 60004
980[6] = 974
980[14] = 65000
980[7] = 975
980[15] = 65001
7.4.11 Parameter 65000 read/write
Used with telegram 81-83
65000 signed long, preset value 32 bit.
7.4.12 Parameter 65001, read only
Used with telegram 81-84
65001 unsigned long
65001[0] = 0x000
C
0101
Header, Version of parameter structure and numbers of
indexdescribing the encoder.
12 index
and
version 1.01
65001[1] = Operating status
(Bit 4 alarm channel control is always set with profile
version 4.x)
65001[2] = Alarm
65001[3] = Supported alarms
65001[4] = Warning
65001[5] = Warnings supported
65001[6] = 0x00000401
Encoder profile version. Always set to this value.
65001[7] = Operating time
65001[8] = Offset value
65001[9] = Singleturn value,
Scaled value
65001[10] =
Total measuring length, scaled value (Linear = 1)
65001[11] =
Velocity measuring unit, see chapter 8.10.