Acyclic parameter data

59

7.4.10 Parameter 980, read only

This parameter shows the supported parameters

980 unsigned int

980[0] = 918

980[8] = 979

980[16] = 65002

980[1] = 922

980[9] = 61000

980[17] = 65003

980[2] = 925

980[10] = 61001

980[3] = 964

980[11] = 61002

980[4] = 965

980[12] = 61003

980[5] = 971

980[13] = 60004

980[6] = 974

980[14] = 65000

980[7] = 975

980[15] = 65001

7.4.11 Parameter 65000 read/write

Used with telegram 81-83

65000 signed long, preset value 32 bit.

7.4.12 Parameter 65001, read only

Used with telegram 81-84

65001 unsigned long

65001[0] = 0x000

C

0101

Header, Version of parameter structure and numbers of

indexdescribing the encoder.

12 index

and

version 1.01

65001[1] = Operating status

(Bit 4 alarm channel control is always set with profile

version 4.x)

65001[2] = Alarm

65001[3] = Supported alarms

65001[4] = Warning

65001[5] = Warnings supported
65001[6] = 0x00000401

Encoder profile version. Always set to this value.

65001[7] = Operating time

65001[8] = Offset value

65001[9] = Singleturn value,

Scaled value

65001[10] =

Total measuring length, scaled value (Linear = 1)

65001[11] =

Velocity measuring unit, see chapter 8.10.