Functionality in the PROFIBUS DPV2 device
68
8.3 G1_XIST1 Preset control
This parameter controls the effect of a preset on the G1_XIST1
actual value.
If Class 4 functionality is activated and G1_XIST1 Preset control is
disabled, the position value in G1_XIST1 will not be affected by a
Preset.
Attribute
Meaning
Value
Enable
G1_XIST1 is affected by a preset
command
0
Disable
Preset does not affect G1_XIST1
1
Table 33
G1_XIST1 Preset control attributes
Note: This parameter is disabled by setting the value to 1.
Note: There is no functionality of this parameter if the class 4
functionality parameter is disabled.
8.4 Scaling function control
This parameter enables or disables the Scaling function of the
encoder.
Attribute
Meaning
Value
Enable
Scaling function is enabled
1
Disable
Scaling function is disabled
0
Table 34
Scaling function control attributes
Note: Class 4 functionality must be enabled to use this
parameter