Functionality in the PROFIBUS DPV2 device

73

8.8 Scaling function parameters

The scaling function converts the encoder’s physical absolute

position value by means of software in order to change the

resolution of the encoder. The scaling parameters will only be

activated if the parameter Class 4 functionality and Scaling

function control are enabled. The permissible value range for the

scaling is limited by the resolution of the encoder.

Singleturn encoders up to 31 bit and multiturn encoders up to 37

bits resolution are

supported by the encoder gateway. When using encoders with

higher resolution than 31 bits together with the encoder gateway,

telegram 84 must be used.

8.8.1 Measuring units per revolution

This parameter sets the singleturn resolution of the encoder. In

other words it is the number of different measuring steps during

one revolution of the encoder.

Example

: For a 13-bit encoder with a single turn resolution of

13 bits the permissible value range for "Measuring

units per revolution" is between 20 and 213 (8192).

Parameter

Meaning

Data type

Measuring units per

revolution

The single turn resolution in

measuring steps

Unsigned 32

Measuring units per

revolution 64 bit

The single turn resolution in

measuring steps for encoders with a

resolution exceeding 32 bits.

Unsigned 64

Table 39

Single turn scaling parameters

Note: The parameter Measuring units per revolution 64 bit is

only supported by the encoder gateway.


Note: After downloading new scaling parameters, the preset

function must be used to set the encoder starting
point to absolute position 0 or to any required starting
position within the scaled operating range.