3 parameters 6500 and 65002 -preset value, Parameters 6500 and 65002 -preset value, Table 49 – HEIDENHAIN PROFIBUS-DP (DPV2) User Manual

Page 84: Structure of parameter 65000 preset value, Table 50, Structure of 65002 preset value 64 bit

background image

Functionality in the PROFIBUS DPV2 device

84

8.14.3 Parameters 6500 and 65002 -Preset value

The parameter 65000 and 65002 sets the value for the preset

function. The parameter 65002 should be used if the preset value

exceeds 32 bits. For more information regarding the Preset

function control, see chapter 8.7.

PNU

65000

Significance

Preset value

Data type

Integer32

Access

Read and write

Validity range

Profile specific

Explanation

The preset value sets the value for the preset function. The

preset value can be stored in the non-volatile memory by

PROFIdrive parameter 971 and will be reloaded at each

start up if stored.

Table 49

Structure of parameter 65000 Preset value

PNU

65002

Significance

Preset value 64 bit

Data type

Integer64

Access

Read and write

Validity range

Profile specific

Explanation

The preset value sets the value for the preset function. The

preset value can be stored in the non-volatile memory by

PROFIdrive parameter 971 and will be reloaded at each

start up if stored.

Table 50

Structure of 65002 Preset value 64 bit