Encoder gateway installation

18

2.4 Shielding philosophy

To achieve the highest possible noise immunity and resistance

against other EMI related disturbances the bus and power supply

cables shall always be shielded. The screen should be connected

to ground on both ends of the cable. In certain cases

compensation current might flow over the screen. Therefore a

potential compensation wire is recommended.

2.5 GSD file

In order to start using the PROFIBUS DP gateway, a device

description file needs to be downloaded and imported to the

configuration software. The device description file is called a

G

eneric Station Description file and contains the necessary

implementation parameters needed for a PROFIBUS DP device.

Available GSD files can be downloaded from

www.heidenhain.com

GSD file

Gateway functionality

GSD file

Gateway PROFIBUS DPV2

(For rotary encoders)

ENC_OB21

Gateway PROFIBUS DPV2 (For

linear encoders)

ENC_0918

Table 4

Available GSD file for DPV2 gateway

The GSD data is saved in the PROFIBUS master and transferred

once to the gateway when the system is powered on. If the

gateway has been started with one GSD file and a new GSD file

with a different ID-number shall be used, the gateway needs to be

restarted before it can use the new GSD file.