Functionality in the PROFIBUS DPV2 device

81

8.12 Operating time

The operating time monitor stores the operating time for the

device in operating hours. The operating time is saved every six

minutes in the non-volatile memory in the device. This happens as

long as the device is powered on.

If the operating time function is not used the operating time value

is set to the maximum value (0xFFFF FFFF).

Parameter

Meaning

Data type

Operating time

The accumulated power on time

Unsigned32

Table 45

Operating time parameter

Note: The parameter Operating time is only supported by

the absolute encoder and encoder gateway in DPV1.


8.13 Offset value

The offset value is calculated in the preset function and shifts the

position value with the calculated value. The offset value is stored

in a non volatile memory and can be read from the encoder at any

time. The data type for the offset value is a 32 bit or 64 bit binary

value with sign, whereby the offset value range is equal to the

measuring range of the device.

The preset function is used after the scaling function. This means

that the offset value is indicated according to the scaled resolution

of the device.

Parameter

Meaning

Data type

Offset value

The offset value for encoders with a

measuring range of maximum 32 bits

Integer32

Offset value 64 bit

The offset value for encoders with a

measuring range exceeding 32 bits.

Integer64

Table 46

Offset value parameter

Note: The offset value is read only and cannot be modified

by a parameter write access.