Alarms and warnings

52

6.3 Faults

If a fault occurs, the corresponding identifier is signaled in a

diagnostic telegram. Faults can be cleared after the sensor error is

acknowledged by the controller by setting bit 15 in the Control

word (G1_STW). A fault is only cleared when the functionality is

within the specification and the position value correct. A going

fault is indicated by a diagnostic telegram without the previously

sent fault.

Definition

Error type

Position error

22

Memory error

24

Table 21

Faults

Error type: 22
Definition: Position value error

GSD entries:

Channel_Diag (22) = "Position value error"

Channel_Diag_Help (22) = The encoder has an internal error and is

not able to provide an accurate position value, change encoder"

Error type: 24
Definition: Memory error

GSD entries:

Channel_Diag (24) = "Memory error"

Channel_Diag_Help (24) = "The encoder has an internal error and

is not able to provide an accurate position value, change encoder"