PROFIBUS IO data description

39

5.4 Standard telegrams

Configuration of the devices is made by choosing different

telegram structures. The telegrams are used to specify the data

length and which type of data that are sent to and from the

master. The supported telegrams for the different devices are

shown in table 12 below.

Telegram

Encoder gateway

Absolute encoder

Standard telegram 81

Supported

Supported

Standard telegram 82

Supported

Not supported

Standard telegram 83

Supported

Not supported

Standard telegram 84

Supported

Not supported

Table 12

Supported telegrams



5.4.1 Standard telegram 81

Standard telegram 81 uses 4 bytes for output data from the

master to the device and 12 bytes of input data from the device to

the master.

Output data from the master:
2 bytes Control word 2 (STW2_ENC)

2 bytes Control word (G1_STW)

IO Data (word)

1

2

Set point

STW2_ENC

G1_STW

Input data to the master:
2 bytes Status word 2 (ZSW2_ENC)

2 bytes Status word (G1_ZSW)

4 bytes Position value 1 (G1_XIST1)

4 bytes Position value 2 (G1_XIST2)

IO Data (word)

1

2

3

4

5

6

Actual value

ZSW2_ENC

G1_ZSW

G1_XIST1

G1_XIST2